Product Catalog

Use the catalog to compare instruments by measurement range, process medium, pressure, output/interface and installation method, then open a card for PDF datasheets and RFQ details.

Easidew PRO I.S.
MICHELL

Easidew PRO I.S.

  • Range: -110 to +20 deg Cdp
  • Accuracy: +/-1 deg Cdp
  • Output: 2-wire 4-20 mA
View Details
Easidew 34 / Easidew M12
MICHELL

Easidew 34 / Easidew M12

  • Range: -110 to +20 deg Cdp
  • Accuracy: +/-2 deg Cdp
  • Dew point or ppmV output
View Details
Easidew Online
MICHELL

Easidew Online

  • Range: -100 to +20 deg Cdp
  • 0-3000 ppmV option
  • 4-20 mA or 0-20 mA output
View Details
Easidew PRO XP
MICHELL

Easidew PRO XP

  • Range: -110 to +20 deg Cdp
  • Accuracy: +/-1 deg Cdp
  • 2-wire 4-20 mA output
View Details
GPR-1000 / GPR-1100 / GPR-2000 / GPR-3500
AII

GPR-1000 / GPR-1100 / GPR-2000 / GPR-3500

  • O2 ranges: 0-10 ppm to 0-100%
  • 0.1 ppm capability depending on model
  • Battery life up to 30 days
View Details
GPR-1500
AII

GPR-1500

  • Trace oxygen down to 0-10 ppm
  • Lower detection limit to 0.05 ppm
  • User-configurable ranges
View Details
GPR-1500 GB / GPR-2500 GB
AII

GPR-1500 GB / GPR-2500 GB

  • Range: 0-10 ppm to 0-25% O2
  • Accuracy better than 2% of selected range
  • 4-20 mA output
View Details
GPR-1600 / GPR-2600 / GPR-3100
AII

GPR-1600 / GPR-2600 / GPR-3100

  • Trace ppm to oxygen purity measurement
  • Accuracy down to +/-0.02 ppm in the lowest range
  • Four ranges with manual or automatic ranging
View Details
GPR-1900 / GPR-2900
AII

GPR-1900 / GPR-2900

  • Range: 0-10 ppm to 0-100% O2
  • Accuracy better than 2% of selected range
  • Two configurable alarms
View Details
HC2A-IC / HC2A-IM / HC2A-IE
ROTRONIC

HC2A-IC / HC2A-IM / HC2A-IE

  • 0-100% RH
  • Operating range up to -100 to 200 deg C
  • Accuracy +/-0.8% RH, +/-0.1 K at 23 deg C
View Details
HC2A Series
ROTRONIC

HC2A Series

  • 0-100% RH
  • Standard probe range -50 to 100 deg C
  • Accuracy +/-0.8% RH or +/-0.5% RH
View Details
HP31 / HP32
ROTRONIC

HP31 / HP32

  • Operating range: -10 to 60 deg C, 0-100% RH
  • HP31: +/-2% RH / +/-0.3 deg C at 23 deg C
  • 64,000 data point memory
View Details
MDM300 / MDM300 I.S.
MICHELL

MDM300 / MDM300 I.S.

  • Accuracy +/-1 deg Cdp from -60 to +20 deg Cdp
  • T95 to -60 deg Cdp in under 15 minutes
  • Pressure measurement up to 350 barg
View Details
Optidew-HZ
MICHELL

Optidew-HZ

  • Dew-point range: -40 to +120 deg C
  • Dew-point accuracy +/-0.15 deg C
  • 5.7 inch color touchscreen
View Details
SF82 Online
MICHELL

SF82 Online

  • Range: -60 to +60 deg Cdp
  • Accuracy +/-2 deg Cdp
  • 4-20 mA output
View Details
Pura
MICHELL

Pura

  • Dew-point and trace moisture measurement
  • Compact body for system integration
  • Industrial analog output
View Details
HygroFlex1
ROTRONIC

HygroFlex1

  • Relative humidity and temperature measurement
  • Compact wall-mount design
  • Analog output for monitoring systems
View Details
HMT370EX
VAISALA

HMT370EX

  • Humidity and temperature measurement
  • Hazardous-area versions
  • Multiple probe options for different conditions
View Details
HMT310
VAISALA

HMT310

  • Relative humidity and temperature measurement
  • Probe options for different installation methods
  • Industrial output signal
View Details
HMP3 / HMPX
VAISALA

HMP3 / HMPX

  • Humidity and temperature measurement
  • Probe design for integration
  • Compatibility with Vaisala monitoring systems
View Details
DMT153
VAISALA

DMT153

  • Dew-point measurement
  • Compact format for equipment installation
  • Industrial output signal
View Details
DMT143 / DMT143L
VAISALA

DMT143 / DMT143L

  • Dew-point measurement in dry gases
  • Miniature transmitter design
  • Standard and long probe versions
View Details
Chat with us
Industrial measurement product catalog | SenseMeter